SCIENTIFIC HUB

Araştırmanın izini sürün.

SCIENTIFIC LITERATURE · MED

Parkinson hastaları için yüksek çözünürlüklü SPECT kullanarak istatistiksel görüntü analizi için I-123 FP-CIT şablonunun oluşturulması ve doğrulanması.

Creation and validation of an I-123 FP-CIT template for statistical image analysis using high-resolution SPECT for parkinsonian patients.

Makine çevirisi · Editoryal inceleme bekliyor

Ann Nucl Med · 2016-05-25

DOI: 10.1007/s12149-016-1085-8PMID: 27225162

Open accessresearch-article; Validation Study; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

ObjectiveThe aim of this study was to create a new template for the anatomical normalization of I-123 FP-CIT SPECT images of Japanese people to evaluate dopamine transporter binding.MethodsThe subjects consisted of 16 normal control subjects (5 females and 11 males; mean age ± SD, 51.6 ± 9.5 years, ranging from 25 to 62 years) and 21 parkinsonian patients (7 females and 14 males; mean age ± SD, 70.7 ± 9.4 years, ranging from 49 to 85 years). All normal control subjects and 21 patients with parkinsonism underwent MRI. A total of 148 MBq of I-123 FP-CIT was intravenously injected as a bolus, and a SPECT scan was started 4 h later. Data were analyzed with the Statistical Parametric Mapping 8 (SPM8) software. At first, I-123 FP-CIT SPECT images were co-registered to MRI images and MRI images were normalized to Montreal Neurological Institute (MNI) space using a gray.nii template. Co-registered I-123 FP-CIT SPECT images were normalized using the predetermined normalization parameters for MRI images. Then, anatomically normalized I-123 FP-CIT SPECT images were divided by background counts individually measured using ROIs set on the cerebral cortices. The I-123 FP-CIT template was created by averaging the normalized SPECT images of the 16 normal control subjects. Thereafter, the averaged MRI images of the 16 normal control subjects were also created.ResultsA visual inspection revealed that there were no apparent differences between the I-123 FP-CIT images subjected to the two methods of anatomical normalization in normal control subjects. However, a group comparison by a paired t test using SPM8 revealed that the I-123 FP-CIT binding was significantly higher in the substriatal and temporal regions in I-123 FP-CIT images directly normalized with the I-123 FP-CIT template than in those normalized by the predetermined parameters with MRI, while it was higher in the bilateral frontal cortical regions in the latter than in the former images.ConclusionWe successfully created an I-123 FP-CIT template for Japanese people. This template is thought to be useful and reliable for the statistical analysis of I-123 FP-CIT images, although some problems exist in the evaluation of parkinsonian patients. The results of a paired t test using SPM suggest that we should use the same normalization method in statistical image analyses.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.