SCIENTIFIC HUB

Araştırmanın izini sürün.

SCIENTIFIC LITERATURE · MED

Swiftscan Adımını Kullanarak Dopamin Transporter Görüntüleme için Daha Hızlı Toplama ve Görsel ve Yarıkantitatif Analiz Yapmadan Sürekli SPECT Vur.

Faster Acquisition for Dopamine Transporter Imaging Using Swiftscan Step and Shoot Continuous SPECT Without Impairing Visual and Semiquantitative Analysis.

Makine çevirisi · Editoryal inceleme bekliyor

Front Med (Lausanne) · 2020-06-18

DOI: 10.3389/fmed.2020.00235PMID: 32626716

Open accessresearch-article; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

Aim: Dopamine transporter (DAT) imaging with [123I] FP-CIT (DaTSCAN) is an established diagnostic tool in parkinsonism and dementia. Using a low energy high resolution and sensitivity (LEHRS) collimator and step and shoot continuous scanning mode, Swiftscan single photon emission computed tomography (SPECT) (GE Healthcare) enhances sensitivity and enables time or dose reduction. In this phantom and clinical study, we aim to validate a 25% reduction of the acquisition time using Swiftscan and its lack of effect on visual or quantitative analysis. Methods: Anthropomorphic striatal phantom with fillable striata was used. SPECT data from 30 normals (12 men, 18 women; age range, 39-91 years; mean, 71 years ± 11) and 30 patients with Parkinson disease or other neurodegenerative disease with extra-pyramidal syndrome (16 men, 14 women; age range, 43-84 years; mean, 69 years ± 10) were also included. Both phantom and clinical data were acquired using Swiftscan and reconstructed with full-time and 25%-time reduction. Striatal binding ratios (SBRs) were calculated using DaTQUANT software. Results: Both in phantom experiments and in clinical cases, visual analysis remained stable and SBRs were not significantly different whether using Swiftscan or Swiftscan with 25%-time reduction (p Conclusion: Using Swiftscan step and shoot continuous SPECT mode, 25%-time reduction can be applied to DaTSCAN acquisition protocols, without impairing visual or quantitative analysis.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.