SCIENTIFIC HUB

Araştırmanın izini sürün.

SCIENTIFIC LITERATURE · MED

Parkinson hastalarında duodenal levodopa infüzyonu için PEG-J değişimi: retrospektif bir çalışma.

PEG-J replacement for duodenal levodopa infusion in Parkinson's disease patients: a retrospective study.

Makine çevirisi · Editoryal inceleme bekliyor

BMC Neurol · 2022-01-13

DOI: 10.1186/s12883-021-02546-5PMID: 35026993

Open accessresearch-article; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

BackgroundReducing percutaneous endoscopic gastrostomies with jejunal extension tubes (PEG-J) related complications is vital to the long-term preservation of duodenal levodopa infusion (DLI) in advanced Parkinson's disease (APD). Here, we provide data on the frequency of complications for both the standard "pull" and the non-endoscopic, radiologic assisted, "push" replacement PEG-J techniques in APD.MethodsWe retrospectively identified all patients treated with DLI from October 2009 to January 2020 at the Movement Disorders Center. Patients features and demographics, PEG-J procedures, causes for any discontinuation, reported complications and mortality were collected. In this cohort, PEG-J replacements were performed using the standard "pull" procedure or the radiologic assisted "push" method. Descriptive statistical analysis, t-test and paired t-test with False Discovery Rate correction was performed.ResultsThis retrospective study included 30 APD patients [median age 72 ± 5.6 years; mean disease duration 17.2 + 5.7 years]. Mean treatment duration was 35.6 (30.6) months. Overall, 156 PEG-J procedures were performed, and Nineteen patients (63.3%) had a total of 185 reported complications, 85 of which were peristomal complications. 17 (56.6%) underwent 100 replacement procedures due to complications. The most commonly reported complication for replacement was J-tube dislocation (36%). One patient discontinued treatment after 6 months, due to peripheral neuropathy. Six patients died for causes not related to DLI. PEG-J replacements performed with the "push" method had a higher turnover (5.6 vs. 7.6 mo.), but fewer reported complications (67 vs. 75%).ConclusionThe overall rate of complications was lower for "push" technique. This result might have been due to a higher replacement turnover that acted as a protective factor.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.