SCIENTIFIC HUB

Araştırmanın izini sürün.

SCIENTIFIC LITERATURE · MED

Sensör Ölçümleri, Parkinson Hastalığı ve Rehber Terapisinde Motor, Motor Olmayan ve Yaşam Kalitesi Puanlarını Geliştirmek İçin Dalgalanmaları Karakterize Edebilir ve Aşınmaya Son Verebilir.

Sensor Measurements Can Characterize Fluctuations and Wearing Off in Parkinson's Disease and Guide Therapy to Improve Motor, Non-motor and Quality of Life Scores.

Makine çevirisi · Editoryal inceleme bekliyor

Front Aging Neurosci · 2022-03-23

DOI: 10.3389/fnagi.2022.852992PMID: 35401155

Open accessresearch-article; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

ObjectivesThe aim was to examine the role of sensor measurement in identifying and managing fluctuations in bradykinesia of Parkinson's Disease.MethodClinical scales and data from wearable sensors obtained before and after optimization of treatment from 107 participants who participated in a previous study was used. Fluctuators were identified by a levodopa response or wearing off in their sensor data and were subdivided according to whether the sensor's bradykinesia scores were in target range, representing acceptable bradykinesia for part of the dose (Controlled Fluctuator: n = 22) or above target for the whole dose period (Uncontrolled Fluctuator; n = 28). Uncontrolled Non-fluctuators (n = 24) were cases without a levodopa response or wearing-off and sensor bradykinesia scores above target throughout the day (un-controlled). Controlled Non-fluctuators (n = 33) were below target throughout the day (controlled) and used as a reference for good control (MDS-UPDRS III = 33 ± 8.6 and PDQ39 = 28 ± 18).ResultsTreating Fluctuators significantly improved motor and quality of life scores. Converting fluctuators into Controlled Non-fluctuators significantly improved motor, non-motor and quality of life scores and a similar but less significant improvement was obtained by conversion to a Controlled Fluctuator. There was a significantly greater likelihood of achieving these changes when objective measurement was used to guide management.ConclusionsThe sensor's classification of fluctuators bore a relation to severity of clinical scores and treatment of fluctuation improved clinical scores. The sensor measurement aided in recognizing and removing fluctuations with treatment and resulted in better clinical scores, presumably by assisting therapeutic decisions.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.