SCIENTIFIC HUB

Araştırmanın izini sürün.

SCIENTIFIC LITERATURE · MED

Parkinson hastalığında motor komplikasyonları ve tedaviyi değerlendirmek için giyilebilir bir atalet sensörünün fizibilitesi.

Feasibility of a wearable inertial sensor to assess motor complications and treatment in Parkinson's disease.

Makine çevirisi · Editoryal inceleme bekliyor

PLoS One · 2023-02-02

DOI: 10.1371/journal.pone.0279910PMID: 36730238

Open accessresearch-article; Journal Article; Observational StudyKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

BackgroundWearable sensors-based systems have emerged as a potential tool to continuously monitor Parkinson's Disease (PD) motor features in free-living environments.ObjectivesTo analyse the responsivity of wearable inertial sensor (WIS) measures (On/Off-Time, dyskinesia, freezing of gait (FoG) and gait parameters) after treatment adjustments. We also aim to study the ability of the sensor in the detection of MF, dyskinesia, FoG and the percentage of Off-Time, under ambulatory conditions of use.MethodsWe conducted an observational, open-label study. PD patients wore a validated WIS (STAT-ONTM) for one week (before treatment), and one week, three months after therapeutic changes. The patients were analyzed into two groups according to whether treatment changes had been indicated or not.ResultsThirty-nine PD patients were included in the study (PD duration 8 ± 3.5 years). Treatment changes were made in 29 patients (85%). When comparing the two groups (treatment intervention vs no intervention), the WIS detected significant changes in the mean percentage of Off-Time (p = 0.007), the mean percentage of On-Time (p = 0.002), the number of steps (p = 0.008) and the gait fluidity (p = 0.004). The mean percentage of Off-Time among the patients who decreased their Off-Time (79% of patients) was -7.54 ± 5.26. The mean percentage of On-Time among the patients that increased their On-Time (59% of patients) was 8.9 ± 6.46. The Spearman correlation between the mean fluidity of the stride and the UPDRS-III- Factor I was 0.6 (p = ConclusionsIt's feasible to use this sensor for monitoring PD treatment under ambulatory conditions. This system could serve as a complementary tool to assess PD motor complications and treatment adjustments, although more studies are required.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.