SCIENTIFIC HUB

Araştırmanın izini sürün.

SCIENTIFIC LITERATURE · MED

Eu ⁇ sub>2 ⁇ /sub>O ⁇ sub>3 ⁇ /sub>@Cr ⁇ sub>2 ⁇ /sub>O ⁇ sub>3 ⁇ /sub> Nanopartiküller-Modifiye Karbon Yapıştır Elektrodu, Nörotransmitterlerin Verimli Elektrokimyasal Algılaması için Precursor L-DOPA.

Eu<sub>2</sub>O<sub>3</sub>@Cr<sub>2</sub>O<sub>3</sub> Nanoparticles-Modified Carbon Paste Electrode for Efficient Electrochemical Sensing of Neurotransmitters Precursor L-DOPA.

Makine çevirisi · Editoryal inceleme bekliyor

Biosensors (Basel) · 2023-01-29

DOI: 10.3390/bios13020201PMID: 36831967

Open accessresearch-article; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

There are ten million people in the world who have Parkinson's disease. The most potent medicine for Parkinson's disease is levodopa (L-DOPA). However, long-term consumption of L-DOPA leads to the appearance of side effects, as a result of which the control and monitoring of its concentrations are of great importance. In this work, we have designed a new electrochemical sensor for detecting L-DOPA using a carbon paste electrode (CPE) modified with Eu2O3@Cr2O3 composite nanoparticles. Rare earth elements, including Eu, are increasingly used to design new electrode nanocomposites with enhanced electrocatalytic properties. Europium has been considered a significant lanthanide element with greater redox reaction behavior. We conducted a hydrothermal synthesis of Eu2O3@Cr2O3 and, for the first time, the acquired nanoparticles were used to modify CPE. The proposed Eu2O3@Cr2O3/CPE electrode was investigated in terms of its electrocatalytic properties and then used to develop an analytical method for detecting and quantifying L-DOPA. The proposed sensor offers a wide linear range (1-100 µM), high sensitivity (1.38 µA µM-1 cm-2) and a low detection limit (0.72 µM). The practical application of the proposed sensor was investigated by analyzing commercially available pharmaceutical tablets of L-DOPA. The corresponding results indicate the excellent potential of the Eu2O3@Cr2O3/CPE sensor for application in real-time L-DOPA detection.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.