Hastalıklı yürüyüşlerin gerçek dünya koşullarında değerlendirilmesi için çok sensörlü giyilebilir bir sistem.

A multi-sensor wearable system for the assessment of diseased gait in real-world conditions.

Makine çevirisi · Editoryal inceleme bekliyor

Front Bioeng Biotechnol · 2023-04-21

DOI: 10.3389/fbioe.2023.1143248PMID: 37214281

Open accessresearch-article; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

Introduction: Accurately assessing people's gait, especially in real-world conditions and in case of impaired mobility, is still a challenge due to intrinsic and extrinsic factors resulting in gait complexity. To improve the estimation of gait-related digital mobility outcomes (DMOs) in real-world scenarios, this study presents a wearable multi-sensor system (INDIP), integrating complementary sensing approaches (two plantar pressure insoles, three inertial units and two distance sensors). Methods: The INDIP technical validity was assessed against stereophotogrammetry during a laboratory experimental protocol comprising structured tests (including continuous curvilinear and rectilinear walking and steps) and a simulation of daily-life activities (including intermittent gait and short walking bouts). To evaluate its performance on various gait patterns, data were collected on 128 participants from seven cohorts: healthy young and older adults, patients with Parkinson's disease, multiple sclerosis, chronic obstructive pulmonary disease, congestive heart failure, and proximal femur fracture. Moreover, INDIP usability was evaluated by recording 2.5-h of real-world unsupervised activity. Results and discussion: Excellent absolute agreement (ICC >0.95) and very limited mean absolute errors were observed for all cohorts and digital mobility outcomes (cadence ≤0.61 steps/min, stride length ≤0.02 m, walking speed ≤0.02 m/s) in the structured tests. Larger, but limited, errors were observed during the daily-life simulation (cadence 2.72-4.87 steps/min, stride length 0.04-0.06 m, walking speed 0.03-0.05 m/s). Neither major technical nor usability issues were declared during the 2.5-h acquisitions. Therefore, the INDIP system can be considered a valid and feasible solution to collect reference data for analyzing gait in real-world conditions.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.