SCIENTIFIC HUB

Araştırmanın izini sürün.

SCIENTIFIC LITERATURE · MED

Görüntü kodlu biyolojik ve biyolojik olmayan değişkenler, çok siteli nörogörüntüleme verileri üzerinde eğitilmiş derin öğrenme modellerinde kısayol olarak kullanılabilir.

Image-encoded biological and non-biological variables may be used as shortcuts in deep learning models trained on multisite neuroimaging data.

Makine çevirisi · Editoryal inceleme bekliyor

J Am Med Inform Assoc · 2023-11-01

DOI: 10.1093/jamia/ocad171PMID: 37669158

Open accessResearch Support, Non-U.S. Gov't; research-article; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

ObjectiveThis work investigates if deep learning (DL) models can classify originating site locations directly from magnetic resonance imaging (MRI) scans with and without correction for intensity differences.Material and methodsA large database of 1880 T1-weighted MRI scans collected across 41 sites originally for Parkinson's disease (PD) classification was used to classify sites in this study. Forty-six percent of the datasets are from PD patients, while 54% are from healthy participants. After preprocessing the T1-weighted scans, 2 additional data types were generated: intensity-harmonized T1-weighted scans and log-Jacobian deformation maps resulting from nonlinear atlas registration. Corresponding DL models were trained to classify sites for each data type. Additionally, logistic regression models were used to investigate the contribution of biological (age, sex, disease status) and non-biological (scanner type) variables to the models' decision.ResultsA comparison of the 3 different types of data revealed that DL models trained using T1-weighted and intensity-harmonized T1-weighted scans can classify sites with an accuracy of 85%, while the model using log-Jacobian deformation maps achieved a site classification accuracy of 54%. Disease status and scanner type were found to be significant confounders.DiscussionOur results demonstrate that MRI scans encode relevant site-specific information that models could use as shortcuts that cannot be removed using simple intensity harmonization methods.ConclusionThe ability of DL models to exploit site-specific biases as shortcuts raises concerns about their reliability, generalization, and deployability in clinical settings.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.