Parkinson hastalığında derin beyin stimülasyonu: çerçeve tabanlı, çerçevesiz ve çerçevesiz fiducial-less tekniklerin doğruluk ve klinik sonuçlarının karşılaştırılması.

Deep brain stimulation in Parkinson's disease: a comparison of accuracy and clinical outcomes of frame-based, frameless and frameless fiducial-less techniques.

Makine çevirisi · Editoryal inceleme bekliyor

Neurol Sci · 2025-03-13

DOI: 10.1007/s10072-025-08102-0PMID: 40080370

Open accessComparative Study; research-article; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

BackgroundThe effectiveness of deep brain stimulation (DBS) for Parkinson's disease (PD) depends on implantation accuracy. DBS initially employed a stereotactic frame (frame-based, FB), but technological advancements led to the development of less invasive methods based on fiducial markers (F + F) or intraoperative imaging (F-F). This study compares the accuracy and efficacy of three DBS-STN implantation techniques.MethodsThis retrospective study involved 18 patients with PD who underwent bilateral STN DBS between 2018 and 2023. Patients were divided into three groups: FB (n = 6), F + F (n = 7), and F-F (n = 5). Postoperative CT and preoperative MRI fusion were used to evaluate electrode accuracy via deviations from planned targets in x, y, z axes, and calculate the radial error (RE) and vector error (VE). We analyzed Unified Parkinson's Disease Rating Scale (UPDRS) III scores in four "on/off medication-stimulation" combinations, LEDD, and disease stage before DBS, and 3 and 12 months post-DBS.ResultsNo statistically significant differences were observed between the three methods in|Δx| (FB = 1.30 ± 0.91; F + F = 1.05 ± 0.93; F-F = 1.33 ± 1.09 mm),|Δy| (FB = 0.95 ± 0.98; F + F = 1.11 ± 1.17; F-F = 1.28 ± 1.14 mm), RE (FB = 1.82 ± 0.29; F + F = 1,71 ± 0,36; F-F = 1,91 ± 1,49 mm) and VE (FB = 3,14 ± 0,35 mm; F + F = 4,92 ± 0,54 mm; F-F = 4,42 ± 1,22 mm). All groups demonstrated significant UPDRS III (> 50%) and LEDD reduction (> 40%) at 12 months, with no intergroup differences.ConclusionsThe study concludes that all three techniques provide equivalent accuracy and clinical efficacy. Centers should select DBS-STN methods based on available resources and expertise.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.