Parkinson hastalığı ve atipik Parkinson sendromlu hastalarda hastane ve günlük yaşam hareketliliğinde enstrümanlı yürüyüş değerlendirmelerinin geçerliliğini inşa edin: keşif çalışması.

Construct validity of instrumented gait assessments in hospital and daily life mobility in patients with Parkinson's disease and atypical Parkinson's syndromes: an exploratory study.

Makine çevirisi · Editoryal inceleme bekliyor

J Neurol · 2026-02-09

DOI: 10.1007/s00415-026-13652-0PMID: 41656377

Open accessresearch-article; Validation Study; Multicenter Study; Randomized Controlled Trial; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

Background and aimParkinsonian disorders are hallmarked by gait and balance impairments. Atypical parkinsonian disorders (APD) develop postural instability with falls and gait disorders early on. Sensor-based gait recordings provide objective data in hospital and everyday life, improving mobility assessment accuracy. However, the impact of duration and distance of instrumented assessments on construct validity remains unclear. This exploratory study aims to evaluate the construct validity of gait assessments compared with clinical, functional, and patient-reported scores.MethodsThe multi-centered Mobility_APP study recruited 43 PD and 49 APD patients. Among others, the Berg Balance Scale (BBS) and the postural instability and gait difficulty score (PIGD) were collected. Sensor-based gait parameters were captured during standardized 2 × 10 m and 2-min walk tests (2MWT) in the hospital and for 1 day of physical activity monitoring (PAM) at home. PAM was categorized by short (10-30 s), medium (30-60 s), and long (≥ 60 s) walking bouts (WB). Spearman correlations were applied to investigate associations between scores.ResultsMean gait velocity (GV) and stride length correlated more strongly with functional, clinical, and patient-reported scores in 2MWT than in 2 × 10 m. Additionally, the GV variability in the 2MWT correlated with BBS and PIGD (r = │0.3-0.7│), but was less prominent in 2 × 10 m (r = │0.0-0.5│). In PAM, GV of long WB correlated more strongly with the PIGD (r = │0.5-0.6│) than short WB (r = │0.2-0.4│).ConclusionThe 2MWT tended to show the highest construct validity. PAM offered complementary but weaker correlations, highlighting that PAM provides novel insights into daily life mobility of APD patients.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.