SCIENTIFIC HUB

Araştırmanın izini sürün.

SCIENTIFIC LITERATURE · MED

Pallidal derin beyin stimülasyonunu lokalize etmek için yeni bir metodoloji.

A novel methodology for localizing pallidal deep brain stimulation leads.

Makine çevirisi · Editoryal inceleme bekliyor

Front Neuroanat · 2026-02-23

DOI: 10.3389/fnana.2026.1768558PMID: 41809057

Open accessmethods-article; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

IntroductionPositioning of deep brain stimulation (DBS) leads is paramount for optimizing therapeutic efficacy in Parkinson's disease (PD) and dystonia. Quantitative determination of lead position remains essential; however, current atlas-based targeting and stereotactic coordinate methods, while informative, limit patient specificity afforded by high-resolution reconstruction and introduce subjective variability.MethodsWe developed a novel pipeline in Unity™ to ingest 7T MRI-based reconstructions of DBS leads within the globus pallidus internus (GPi). Using anatomical landmarks and structure-specific algorithms, the GPi was parcellated into 12 anatomically-based subregions in a semi-automated, reproducible manner. Active contact positions were localized relative to a novel coordinate system developed from a GPi-based bounding box. A novel distance-to-border metric remapped contacts onto a common atlas (PD25) for population comparison against the same contacts mapped onto a common left GPi space using mid-commissural point (MCP) coordinates (Schaltenbrand-Wahren atlas).ResultsFifteen leads from 10 PD subjects were used for ellipsoid fitting of active contact locations, resulting in an elliptical volume of 38.94 mm3 when using MCP coordinates, compared to a volume of 5.08 mm3 with our GPi-specific coordinates. The mean distance-to-ellipse centroid was 3.45 ± 1.57 mm for MCP coordinates and 2.03 ± 0.82 for our GPi-specific coordinates. Our distance-to-border remapping metric yielded mean adjustments of 0.81 mm (y-axis) and 1.61 mm (z-axis). A subset of six GPi active contacts were plotted with post-DBS motor improvement scores, demonstrating the ability to link lead location with clinical outcomes.ConclusionOur novel software provides a quantifiable lead location with respect to the anatomical target, enhancing patient-specific lead localization by avoiding some of the pitfalls of either structure-to-atlas normalization or traditional stereotactic coordinates.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.