SCIENTIFIC HUB

Araştırmanın izini sürün.

SCIENTIFIC LITERATURE · MED

Adaptif Derin Beyin Stimülasyonu için Gerçek Zamanlı EKG Artifact Removal: Karşılaştırmalı Bir Çalışma.

Real-Time ECG Artifact Removal for Adaptive Deep Brain Stimulation: A Comparative Study.

Makine çevirisi · Editoryal inceleme bekliyor

Sensors (Basel) · 2026-04-25

DOI: 10.3390/s26092673PMID: 42122398

Open accessComparative Study; research-article; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

BackgroundAdaptive deep brain stimulation (aDBS) for Parkinson's disease (PD) relies on accurate detection of beta oscillatory activity. However, electrocardiographic (ECG) artifacts frequently contaminate local field potentials (LFPs), compromising control algorithms. While offline cleaning methods exist, their feasibility for real-time operation within the strict timing constraints of current sensing-enabled devices remains unknown.MethodsWe evaluated four ECG removal algorithms, template subtraction (TS), singular value decomposition (SVD), extended SVD (eSVD), and the Perceive toolbox (PR), on simulated datasets (contaminated at -30 to +20 dB) and clinical recordings from 20 PD patients. Algorithms were assessed for artifact removal quality (beta power preservation, signal-to-noise ratio) and real-time feasibility (99th percentile processing latency-P99 ResultsOnly TS and standard SVD met the real-time feasibility threshold, with TS achieving superior timing consistency (P99 ≈ 10 ms). eSVD and PR proved incompatible with closed-loop requirements (P99 > 90 ms). While eSVD yielded the highest artifact suppression at extreme contamination, it suffered from poor signal preservation at moderate levels. TS demonstrated the best balance, maintaining beta power accuracy within ±12% across clinically relevant contamination levels.ConclusionsTS is the recommended method for real-time aDBS applications, offering a safety-critical balance of computational efficiency and biomarker fidelity.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.