An <i>in silico</i> cortico-basal ganglia-thalamic testbed for comparing visual and deep brain stimulation in Parkinson's disease.

Front Comput Neurosci · 2026-10-02

DOI: 10.3389/fncom.2026.1950516PMID: 42890761

Erişim kaynaktan kontrol edilmeliJournal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

IntroductionDeep brain stimulation (DBS) is an established intervention for Parkinson's disease (PD), whereas the network-level effects of prescribed periodic visual input implemented with 10 Hz base pulses remain uncertain.MethodsWe developed a conductance-based cortico-basal ganglia-thalamic (CBT) model comprising 11 Hodgkin-Huxley neuronal populations and a prescribed periodic visual-input unit (RET) to compare 130 Hz subthalamic nucleus (STN) DBS with the archived periodic visual-input condition on the same calibrated PD network. Primary conditions used N = 10 independent runs each. Additional analyses included an unpaired 0-5 mA/cm2 DBS-amplitude series, a matched-seed internal-globus-pallidus-to-thalamocortical-relay (GPi→TC) sensitivity analysis at 0.8, 1.0, and 1.2 × nominal coupling (N = 10 per scale), and a matched-seed three-parameter ±20% local sensitivity analysis (N = 5 per parameter-condition cell).ResultsDBS reduced the model-internal STN synaptic-current beta measure from 0.0184 ± 0.0060 to 0.0018 ± 0.0004 a.u. (Holm-corrected p = 1.1 × 10-5), whereas periodic visual input increased thalamocortical relay (TC) and reticular thalamic (RE) firing and enhanced cortical pyramidal (PY) gamma (30-80 Hz) and narrowband 38-42 Hz power. Cortical PY firing was 4.86 ± 0.84 Hz in PD, 5.28 ± 0.87 Hz with DBS (p = 0.285 versus PD), and 10.33 ± 0.85 Hz with periodic visual input (Holm-corrected p = 1.18 × 10-10 versus PD). The ampltude series showed a non-monotonic STN response at 1 mA/cm2; from 2 to 5 mA/cm2, mean STN beta values occupied a narrow range of 0.00186-0.00212 a.u. In the GPi→TC analysis, TC spontaneous firing remained 0 Hz in 30/30 runs, and all 750,000 saved voltage samples were finite and subthreshold (-72.06 to -54.74 mV; no 0-mV crossings). Across the three-parameter analysis, DBS raw STN-beta suppression remained 88.9%-95.8%, and periodic visual input increased TC firing 3.70-4.29-fold relative to nominal PD.DiscussionThese findings show persistence across the tested dose, GPi→TC, and three-parameter local domains but do not establish evoked relay fidelity, global parameter robustness, biological mechanisms, or clinical efficacy.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.