Radiosynthesis and quality control testing of two <sup>18</sup>F-labeled radiopharmaceuticals for α-synuclein imaging in clinical investigations.

EJNMMI Radiopharm Chem · 2026-07-23

DOI: 10.1186/s41181-026-00480-wPMID: 42894080

Open accessresearch-article; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

Background18F-Labeled (E)-1-fluoro-3-((2-(4-(5-(methylamino)pyrazin-2-yl)but-1-en-3-yn-1-yl)benzo[d]thiazol-6-yl)oxy)propan-2-ol ([18F]SPAL-T-06) and (E)-1-fluoro-3-((2-(4-(6-(methylamino)pyridine-3-yl)but-1-en-3-yn-1-yl)benzo[d]thiazol-6-yl)oxy)propan-2-ol ([18F]C05-05) are positron emission tomography (PET) imaging agents for α-synuclein pathologies. Recently, we demonstrated the utility of PET imaging with [18F]SPAL-T-06 for α-synuclein pathologies in patients with multiple system atrophy and with [18F]C05-05 for α-synuclein pathologies in Parkinson's disease and related disorders. In this study, to establish [18F]SPAL-T-06 and [18F]C05-05 as PET radiopharmaceuticals for clinical investigations, we developed routine radiosynthetic procedures using an 18F-labeling synthesizer and performed quality control (QC) testing of these two PET radiopharmaceuticals.Results[18F]SPAL-T-06 and [18F]C05-05 were synthesized by direct 18F-fluorination of their respective tetrahydropyranyl-protected tosylated precursors, followed by deprotection, using an 18F-labeling synthesizer. The non-decay-corrected radiochemical yields of [18F]SPAL-T-06 and [18F]C05-05 from 18F- at the end of synthesis (EOS) were 11 ± 4.6% (n = 19) and 20 ± 6.8% (n = 37), respectively. The radiochemical purities of both PET radiopharmaceuticals exceeded 99%. The molar activities of each PET radiopharmaceutical at EOS exceeded 68 GBq/µmol, and the total synthesis times were within 100 min after irradiation. In addition, [18F]SPAL-T-06 and [18F]C05-05 were efficiently separated from byproducts using a semi-preparative high-performance liquid chromatography system. All QC results for the two PET radiopharmaceuticals complied with in-house QC and quality assurance specifications. The stabilities of the two PET radiopharmaceuticals were evaluated under standard fluorescent light in a general laboratory environment and under UV-cutoff light in a natural light-shielded environment. After 10 min of exposure to the standard fluorescent light, the radiochemical purity of each tracer decreased to approximately 86%. In contrast, the radiochemical purity of each tracer exceeded 99% after 60 min under UV-cutoff light in a natural light-shielded environment.ConclusionsWe successfully prepared two PET radiopharmaceuticals, [18F]SPAL-T-06 and [18F]C05-05, for clinical investigation. The radiosynthesis and QC findings provide a practical basis for establishing standardized production procedures and facilitating technology transfer to other PET centers. In particularly, all post-deprotection radiosynthesis steps and QC testing for [18F]SPAL-T-06 and [18F]C05-05 should be performed under UV-cutoff light in a natural light-shielded environment to prevent photoisomerization.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.