Giyilebilir Teknoloji ile Ayak Bileği Hareket Aralığının Değerlendirilmesi: Karşılaştırmalı Bir Doğruluk ve Güvenilirlik Çalışması

Assessing Ankle Range of Motion with Wearable Technology: A Comparative Accuracy and Reliability Study

Makine çevirisi · Editoryal inceleme bekliyor

· 2025-05-06

DOI: 10.1101/2025.05.02.25326892

Erişim kaynaktan kontrol edilmeliPreprintKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

Background Accurate measurement of ankle range of motion (ROM) is essential for diagnosing and treating musculoskeletal conditions, optimizing athletic performance, and managing neurological disorders such as Parkinson’s disease. This study evaluates the novel Ambulosono device, a sensor-based tool, against the traditional goniometer for assessing Ankle ROM in healthy participants. Methods A comparative cross-sectional study was conducted on 54 healthy participants aged 15 to 24 years. Ankle ROM was measured using the goniometer, placed on the lateral malleolus, and the Ambulosono device, secured on the dorsum of the foot. Participants performed maximal dorsiflexion and plantarflexion with knees extended, and five measurements were taken per device on both feet in randomized order. Statistical analyses included descriptive statistics, Bland-Altman plots, and Intraclass Correlation Coefficients (ICCs) to assess agreement and reliability. Results Mean goniometer ROM was 58.44° (SD=5.54) versus Ambulosono’s 56.80° (SD=3.88). No significant differences emerged between devices, foot sides, or gender. Bland-Altman analysis indicated agreement without P proportional bias. Reliability was excellent (Cronbach’s alpha=0.983, ICC=0.983). Conclusion The Ambulosono device is a robust tool that offers a reliable alternative to traditional goniometry, with advantages such as real-time feedback and reduced inter-rater variability. Its potential applications extend beyond clinical and athletic settings to include neurological rehabilitation and remote patient monitoring. Further research is warranted to validate its efficacy across diverse populations and real-world scenarios.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.