SCIENTIFIC HUB

Araştırmanın izini sürün.

SCIENTIFIC LITERATURE · PPR

Progresif Supranükleer Palsy Alt Tiplerinin ve Parkinson Hastalığının Farklılaştırılması için 123i-fp-cit Spect ve 123i-mibg Stintigrafisinin Kombine Kullanımı

Combined Use of 123i-fp-cit Spect and 123i-mibg Scintigraphy for Differentiation of Progressive Supranuclear Palsy Subtypes and Parkinson's Disease

Makine çevirisi · Editoryal inceleme bekliyor

· 2020-05-14

DOI: 10.21203/rs.3.rs-28108/v1

Erişim kaynaktan kontrol edilmeliPreprintKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

Abstract Background:This study was undertaken to investigate the utility of 123I-ioflupane (123I-FP-CIT) single photon emission computed tomography (SPECT), 123I-metaiodobenzylguanidine (123I-MIBG) scintigraphy and both of these to differentiate among progressive supranuclear palsy (PSP), including typical cases and other subtypes, and Parkinson’s disease (PD).Methods: Twenty-five patients with typical PSP (Richardson's syndrome; PSP-RS), 14 atypical ones (PSP-variants; PSP-V) and 42 PD who underwent both 23I-FP-CIT SPECT and 123I-MIBG scintigraphy within short intervals were enrolled. Specific binding ratio (SBR) of the striatum and midbrain and anteroposterior and asymmetry ratio of the striatal SBR on 123I-FP-CIT SPECT and heart-to-mediastinum (H/M) ratio and washout rate (WR) on 123I-MIBG scintigraphy were used as quantitative measures. The classifier performance based on adaptive boosting was evaluated using five-fold cross-validation for these measures.Results: Midbrain SBR and the striatal anteroposterior ratio were statistically lower in PSP-RS than PD. On the other hand, there were no significant differences in any other quantitative measures among PSP-RS, PSP-V and PD. Striatal and midbrain SBRs and anteroposterior ratio of PSP-V were approximately in-between those of PSP-RS and PD. PD showed the lowest early and delayed H/M ratios and highest WR of any group. The combination of 123I-FP-CIT and 123I-MIBG was useful in discriminating PSP-RS and PSP-V from PD, while 123I-FP-CIT was superior to 123I-MIBG in differentiating PSP-RS from PSP-V.Conclusion: The combination of 123I-FP-CIT SPECT and 123I-MIBG scintigraphy, rather than either alone, may be a useful differential diagnostic tool to differentiate patients with PSP-RS, PSP-V and PD.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.