SCIENTIFIC HUB

Follow the evidence.

SCIENTIFIC LITERATURE · MED

Cardiac sympathetic innervation in Parkinson's disease versus multiple system atrophy.

Clin Auton Res · 2022-02-11

DOI: 10.1007/s10286-022-00853-6PMID: 35149937

Open accessResearch Support, Non-U.S. Gov't; research-article; Journal ArticleOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

PurposeThe aims of this study were to evaluate the diagnostic accuracy of the dual imaging method combining cardiac iodine-123-metaiodobenzylguanidine single-photon emission computed tomography combined with low-dose chest computed tomography compared to routine cardiac scintigraphy, and assess regional differences in tracer distribution and the relationships between imaging and autonomic function in Parkinson's disease and multiple system atrophy.MethodsA prospective study including 19 Parkinson's disease and 12 multiple system atrophy patients was performed. Patients underwent clinical evaluation, iodine-123-metaiodobenzylguanidine single-photon emission computed tomography combined with chest computed tomography, planar scintigraphy, and cardiovascular autonomic function tests.ResultsCo-registration of single-photon emission computed tomography and chest computed tomography resulted in three groups with distinct patterns of tracer uptake: homogeneous, non-homogeneously reduced and absent. There was a significant difference in group allocation among patients with multiple system atrophy and Parkinson's disease (p = 0.001). Most multiple system atrophy patients showed homogeneous uptake, and the majority of Parkinson's disease patients showed absent cardiac tracer uptake. We identified a pattern of heterogeneous cardiac tracer uptake in both diseases with reductions in the apex and the lateral myocardial wall. Sympathetic dysfunction reflected by a missing blood pressure overshoot during Valsalva manoeuvre correlated with cardiac tracer distribution in Parkinson's disease patients (p ConclusionsThe diagnostic accuracy of the dual imaging method and routine cardiac scintigraphy were similar. Anatomical tracer allocation provided by the dual imaging method of cardiac iodine-123-metaiodobenzylguanidine single-photon emission computed tomography and chest computed tomography identified a heterogeneous subgroup of Parkinson's disease and multiple system atrophy patients with reduced cardiac tracer uptake in the apex and the lateral wall. Sympathetic dysfunction correlated with cardiac imaging in Parkinson's disease patients.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.