SCIENTIFIC HUB

Follow the evidence.

SCIENTIFIC LITERATURE · MED

Towards a Modular Pathological Tremor Simulation System Based on the Stewart Platform.

Sensors (Basel) · 2023-11-07

DOI: 10.3390/s23229020PMID: 38005408

Open accessresearch-article; Journal ArticleOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

Wearable technologies have aided in reducing pathological tremor symptoms through non-intrusive solutions that aim to identify patterns in involuntary movements and suppress them using actuators positioned at specific joints. However, during the development of these devices, tests were primarily conducted on patients due to the difficulty of faithfully simulating tremors using simulation equipment. Based on studies characterizing tremors in Parkinson's disease, the development of a robotic manipulator based on the Stewart platform was initiated, with the goal of satisfactorily simulating resting tremor movements in the hands. In this work, a simulator was implemented in a computational environment using the multibody dynamics method. The platform structure was designed in a virtual environment using SOLIDWORKS® v2017 software and later exported to Matlab® R17a software using the Simulink environment and Simscape multibody library. The workspace was evaluated, and the Kalman filter was used to merge acceleration and angular velocity data and convert them into data related to the inclination and rotation of real patients' wrists, which were subsequently executed in the simulator. The results show a high correlation and low dispersion between real and simulated signals, demonstrating that the simulated mechanism has the capacity to represent Parkinson's disease resting tremors in all wrist movements. The system could contribute to conducting tremor tests in suppression devices without the need for the presence of the patient and aid in comparing suppression techniques, benefiting the development of new wearable devices.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.