SCIENTIFIC HUB

Follow the evidence.

SCIENTIFIC LITERATURE · MED

Radiomics incorporating deep features for predicting Parkinson's disease in <sup>123</sup>I-Ioflupane SPECT.

EJNMMI Phys · 2024-07-10

DOI: 10.1186/s40658-024-00651-1PMID: 38985382

Open accessresearch-article; Journal ArticleOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

Purpose123I-Ioflupane SPECT is an effective tool for the diagnosis and progression assessment of Parkinson's disease (PD). Radiomics and deep learning (DL) can be used to track and analyze the underlying image texture and features to predict the Hoehn-Yahr stages (HYS) of PD. In this study, we aim to predict HYS at year 0 and year 4 after the first diagnosis with combined imaging, radiomics and DL-based features using 123I-Ioflupane SPECT images at year 0.MethodsIn this study, 161 subjects from the Parkinson's Progressive Marker Initiative database underwent baseline 3T MRI and 123I-Ioflupane SPECT, with HYS assessment at years 0 and 4 after first diagnosis. Conventional imaging features (IF) and radiomic features (RaF) for striatum uptakes were extracted from SPECT images using MRI- and SPECT-based (SPECT-V and SPECT-T) segmentations respectively. A 2D DenseNet was used to predict HYS of PD, and simultaneously generate deep features (DF). The random forest algorithm was applied to develop models based on DF, RaF, IF and combined features to predict HYS (stage 0, 1 and 2) at year 0 and (stage 0, 1 and ≥ 2) at year 4, respectively. Model predictive accuracy and receiver operating characteristic (ROC) analysis were assessed for various prediction models.ResultsFor the diagnostic accuracy at year 0, DL (0.696) outperformed most models, except DF + IF in SPECT-V (0.704), significantly superior based on paired t-test. For year 4, accuracy of DF + RaF model in MRI-based method is the highest (0.835), significantly better than DF + IF, IF + RaF, RaF and IF models. And DL (0.820) surpassed models in both SPECT-based methods. The area under the ROC curve (AUC) highlighted DF + RaF model (0.854) in MRI-based method at year 0 and DF + RaF model (0.869) in SPECT-T method at year 4, outperforming DL models, respectively. And then, there was no significant differences between SPECT-based and MRI-based segmentation methods except for the imaging feature models.ConclusionThe combination of radiomic and deep features enhances the prediction accuracy of PD HYS compared to only radiomics or DL. This suggests the potential for further advancements in predictive model performance for PD HYS at year 0 and year 4 after first diagnosis using 123I-Ioflupane SPECT images at year 0, thereby facilitating early diagnosis and treatment for PD patients. No significant difference was observed in radiomics results obtained between MRI- and SPECT-based striatum segmentations for radiomic and deep features.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.