SCIENTIFIC HUB

Follow the evidence.

SCIENTIFIC LITERATURE · MED

Concordance and test-retest consistency of sleep biomarker-based neurodegenerative disorder profiling.

Sci Rep · 2024-12-28

DOI: 10.1038/s41598-024-82528-yPMID: 39732824

Open accessresearch-article; Journal ArticleOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

Biomarkers that aid in early detection of neurodegeneration are needed to enable early symptomatic treatment and enable identification of people who may benefit from neuroprotective interventions. Increasing evidence suggests that sleep biomarkers may be useful, given the bi-directional relationship between sleep and neurodegeneration and the prominence of sleep disturbances and altered sleep architectural characteristics in several neurodegenerative disorders. This study aimed to demonstrate that sleep can accurately characterize specific neurodegenerative disorders (NDD). A four-class machine-learning algorithm was trained using age and nine sleep biomarkers from patients with clinically-diagnosed manifest and prodromal NDDs, including Alzheimer's disease dementia (AD = 27), Lewy body dementia (LBD = 18), and isolated REM sleep behavior disorder (iRBD = 15), as well as a control group (CG = 58). The algorithm was validated in a total of 381 recordings, which included the training data set plus an additional AD = 10, iRBD = 18, Parkinson disease without dementia (PD = 29), mild cognitive impairment (MCI = 78) and CG = 128. Test-retest consistency was then assessed in LBD = 10, AD = 9, and CG = 46. The agreement between the NDD profiles and their respective clinical diagnoses exceeded 75% for the AD, LBD, and CG, and improved when NDD participants classified Likely Normal with NDD indications consistent with their clinical diagnosis were considered. Profiles for iRBD, PD and MCI participants were consistent with the heterogeneity of disease severities, with the majority of overt disagreements explained by normal sleep characterization in 27% of iRBD, 21% of PD, and 26% of MCI participants. For test-retest assignments, the same or similar NDD profiles were obtained for 88% of LBD, 86% in AD, and 98% of CG participants. The potential utility for NDD subtyping based on sleep biomarkers demonstrates promise and requires further prospective development and validation in larger NDD cohorts.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.