SCIENTIFIC HUB

Follow the evidence.

SCIENTIFIC LITERATURE · MED

An individualized tractography pipeline for the nucleus basalis of Meynert lateral tract.

Imaging Neurosci (Camb) · 2024-01-11

DOI: 10.1162/imag_a_00067PMID: 40491673

Open accessresearch-article; Journal ArticleOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

BackgroundAt the center of the cortical cholinergic network, the nucleus basalis of Meynert (NBM) is crucial for the cognitive domains most vulnerable in Parkinson's disease (PD). Preclinical evidence has demonstrated the positive impact of NBM deep brain stimulation (DBS) on cognition but early human trials have had mixed results. It is possible that DBS of the lateral NBM efferent white matter fiber bundle may be more effective at improving cognitive-motor function. However, precise tractography modelling is required to identify the optimal target for neurosurgical planning. Individualized tractography approaches have been shown to be highly effective for accurately identifying DBS targets but have yet to be developed for the NBM.MethodsUsing structural and diffusion-weighted imaging, we developed a tractography pipeline using manually segmented regions of interest for precise individualized identification of the lateral NBM target tract. Using dice similarity coefficients, the reliability of the tractography outputs was assessed across three cohorts to investigate: 1) whether this manual segmentation pipeline is more reliable than an existing automatic segmentation pipeline currently used in the literature; 2) the inter- and intra-rater reliability of our pipeline in research scans of patients with PD; and 3) the reliability and practicality of this pipeline in clinical scans of DBS patients.ResultsThe individualized manual pipeline was found to be significantly more reliable than the existing automated pipeline for both the segmentation of the NBM region itself (p 0.6) and intra-rater (mean Dice coefficient >0.7) reliability across runs. Finally, the pipeline was shown to be highly reliable within the clinical scans (mean Dice coefficient = 0.77). However, accurate reconstruction was only evident in 7/10 tracts.ConclusionWe have developed a reliable tractography pipeline for the identification and analysis of the NBM lateral tract in research and clinical-grade imaging of healthy young adult and PD patient scans.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.