SCIENTIFIC HUB

Follow the evidence.

SCIENTIFIC LITERATURE · MED

Chemometric-assisted spectrophotometric approach for stability assessment of safinamide and its synthetic precursor in antiparkinsonian formulation with sustainability profiling.

Sci Rep · 2025-11-29

DOI: 10.1038/s41598-025-28085-4PMID: 41318600

Open accessResearch Support, Non-U.S. Gov't; research-article; Journal ArticleOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

Parkinson's disease (PD) is a significant health issue that affects older individuals. Safinamide mesylate (SAF) is a recently developed adjunct therapy increasingly employed in the management of PD. Ensuring the stability of new drug formulations and establishing suitable stability-indicating methodologies is crucial for pharmaceutical analysis. The current study has developed three new, user-friendly, and robust mathematical methods using multivariate spectrophotometric analysis to quantify SAF, its synthetic precursor impurity (4-HBD), and stress-induced degradation products. The multivariate algorithms used include principal component regression (PCR), partial least squares (PLS), and synergy intervals partial least squares (siPLS). The ranges of the proposed methods were 3.00-23.00, 1.00-5.00, 2.50-6.50, and 5.00-13.00 µg/mL for SAF, 4-HBD, SAF hydrolytic degradation products, and SAF oxidative degradation products, respectively. When analyzed using the applied methods, the commercially available tablet preparation showed stability with no impurities or interference from tablet additives. In terms of accuracy and precision, the statistical analysis also revealed no significant differences in comparison to the reported methods. The developed multivariate models were validated using internal and external validation sets. The results demonstrated that the siPLS model outperformed PCR and PLS based on the root mean square error of prediction (RMSEP) and the correlation coefficient values (r). Furthermore, these methods can be used as a substitute for HPLC in quality control laboratories when multiple samples need to be analyzed within a short timeframe. Finally, various sustainability assessment tools were utilized to evaluate and measure the environmental background of the established methods.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.