SCIENTIFIC HUB

Follow the evidence.

SCIENTIFIC LITERATURE · MED

Biomechanical Challenges of Olecranon Fractures in Patients With Parkinson's Disease: A Case Analysis of Neuro-Orthopedic Collaborative Intervention Strategies.

Cureus · 2025-12-04

DOI: 10.7759/cureus.98493PMID: 41497926

Open accessJournal Article; Case Reports; case-reportOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

In the intricate landscape of Parkinson's disease (PD), patients face a notably elevated risk of fixation failure due to the motor dysfunction characteristic of this condition. This narrative presents a compelling case of recurrent olecranon fractures in a patient with PD. It highlights the clinical implications of a neuro-orthopedic collaborative strategy that is meticulously anchored in quantitative assessment. A 71-year-old male with PD, Unified Parkinson's Disease Rating Scale III (UPDRS III) score 45 and modified Ashworth scale grade 2, sustained a comminuted fracture of the right olecranon (classified as Mayo Clinic type IIB) following a fall. The initial fixation, performed with titanium cables, was followed by a secondary wire fixation. Both fixations ultimately failed, compromised by the biomechanical stresses caused by the tremor and muscle rigidity intrinsic to PD. The third intervention, which combined a plate with tension band wiring, resulted in successful fixation. After undergoing deep-brain stimulation (DBS), which alleviated his tremor symptoms, the patient sustained a contralateral olecranon fracture during rehabilitation. This fracture was effectively managed using the same fixation protocol. A neuro-orthopedic collaborative strategy was carefully implemented, using the UPDRS-III and modified Ashworth scale scores to quantify neurological impairment and guide the choice of fixation methods. Ultimately, successful fixation was achieved after three procedures on the right elbow and one on the left. Notably, post-DBS, the patient showed marked improvement in tremor symptoms and achieved a near-normal range of motion (flexion: 130°, extension lag: 10°) and an excellent Mayo Elbow Performance Score (MEPS) of 95/100 in both elbows during follow-up assessments. This neuro-orthopedic collaborative strategy, firmly based on quantitative assessment, effectively addresses the complex biomechanical challenges inherent in fracture management for patients with PD. This approach not only improves fixation success but also significantly enhances functional outcomes, reflecting meticulous planning and execution at every step.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.