SCIENTIFIC HUB

Follow the evidence.

SCIENTIFIC LITERATURE · PPR

Absolute quantitation of sympathetic nerve activity using 123I-metaiodobenzylguanidine SPECT-CT in neurology

· 2023-12-01

DOI: 10.21203/rs.3.rs-3664613/v1

Check source for accessPreprintOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

Abstract Objective The ability of 123I- metaiodobenzylguanidine (MIBG) sympathetic nerve imaging with three-dimensional (3D) quantitation to clinically diagnose neurological disorders has not been evaluated. This study compared absolute heart counts calculated as mean standardized uptake values (SUVmean) with conventional planar image-based quantitation and assessed the contribution of 123I-MIBG single-photon emission computed tomography (SPECT)-CT to the diagnosis of neurological diseases. Methods Seventy-two patients with neurological diseases were consecutively assessed using early and delayed 123I-MIBG SPECT-CT and planar imaging. Left ventricles were manually segmented in both early and delayed SPECT-CT images, and SUVmean and washout rates (WRs) were calculated. Heart-to-mediastinum ratios (HMRs) and WRs on planar images were conventionally computed. We investigated correlations between planar HMRs and SPECT-CT SUVmeans and between WRs obtained from planar and SPECT-CT images. The cutoff for SPECT-CT WR was defined by linear regression together with normal values of planar WR from a database, and the classification was compared with neurological diagnoses of the patients. We classified the patients according to clinical diagnoses of neurological diseases as follows: controls (n = 6), multiple system atrophy (MSA, n = 7), progressive supranuclear palsy (PSP, n = 17), and Parkinson’s disease or dementia with Lewy bodies (PD/DLB, n = 19), then compared SPECT-CT and planar image parameters among them. Results We found significant correlations between SPECT-CT SUVmean and planar HMR on early and delayed images (R2 = 0.69 and 0.82, p 2 = 0.79, p mean in patients with PSP and MSA tended more towards significance than planar HMR. This trend was similar for SPECT-CT WRs in patients with PSP. Conclusions Absolute heart counts and SUVmean determined using 123I-MIBG SPECT-CT correlated with findings of conventional planar images in patients with neurological diseases. Three-dimensional quantitation with 123I-MIBG SPECT-CT imaging might differentiate patients with PSP and MSA from controls.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.