SCIENTIFIC HUB

Araştırmanın izini sürün.

SCIENTIFIC LITERATURE · MED

Parkinsonizmin Otomatik Tespiti için 123I-Ioflupane Görüntülemede Farklı Yoğunluk Normalleştirme Yöntemleri Arasında Karşılaştırma.

Comparison between Different Intensity Normalization Methods in 123I-Ioflupane Imaging for the Automatic Detection of Parkinsonism.

Makine çevirisi · Editoryal inceleme bekliyor

PLoS One · 2015-06-18

DOI: 10.1371/journal.pone.0130274PMID: 26086379

Open accessComparative Study; Research Support, Non-U.S. Gov't; research-article; Journal ArticleKaynağa git ↗

Araştırma özeti

Aşağıdaki metin kaynak makalenin lisansı doğrulanmış orijinal özetidir. cc by

Intensity normalization is an important pre-processing step in the study and analysis of DaTSCAN SPECT imaging. As most automatic supervised image segmentation and classification methods base their assumptions regarding the intensity distributions on a standardized intensity range, intensity normalization takes on a very significant role. In this work, a comparison between different novel intensity normalization methods is presented. These proposed methodologies are based on Gaussian Mixture Model (GMM) image filtering and mean-squared error (MSE) optimization. The GMM-based image filtering method is achieved according to a probability threshold that removes the clusters whose likelihood are negligible in the non-specific regions. The MSE optimization method consists of a linear transformation that is obtained by minimizing the MSE in the non-specific region between the intensity normalized image and the template. The proposed intensity normalization methods are compared to: i) a standard approach based on the specific-to-non-specific binding ratio that is widely used, and ii) a linear approach based on the α-stable distribution. This comparison is performed on a DaTSCAN image database comprising analysis and classification stages for the development of a computer aided diagnosis (CAD) system for Parkinsonian syndrome (PS) detection. In addition, these proposed methods correct spatially varying artifacts that modulate the intensity of the images. Finally, using the leave-one-out cross-validation technique over these two approaches, the system achieves results up to a 92.91% of accuracy, 94.64% of sensitivity and 92.65 % of specificity, outperforming previous approaches based on a standard and a linear approach, which are used as a reference. The use of advanced intensity normalization techniques, such as the GMM-based image filtering and the MSE optimization improves the diagnosis of PS.

Bilimsel değerlendirme

01

Araştırma sorusu

Sorunun kapsamı orijinal çalışma üzerinden değerlendirilir.

02

Yöntem ve örneklem

Çalışma tasarımı ve örneklem için kaynak makaleyi kontrol edin.

03

Temel bulgular

Bu kayıt için editoryal olarak onaylanmış bulgu özeti henüz yayımlanmadı.

04

Sınırlılıklar

Sonuçların genellenebilirliği, yanlılık ve klinik anlamı ayrıca incelenmelidir.

Bibliyografik veriden yöntem, örneklem veya klinik sonuç çıkarımı yapılmaz.