SCIENTIFIC HUB

Follow the evidence.

SCIENTIFIC LITERATURE · MED

Comparison between Different Intensity Normalization Methods in 123I-Ioflupane Imaging for the Automatic Detection of Parkinsonism.

PLoS One · 2015-06-18

DOI: 10.1371/journal.pone.0130274PMID: 26086379

Open accessComparative Study; Research Support, Non-U.S. Gov't; research-article; Journal ArticleOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

Intensity normalization is an important pre-processing step in the study and analysis of DaTSCAN SPECT imaging. As most automatic supervised image segmentation and classification methods base their assumptions regarding the intensity distributions on a standardized intensity range, intensity normalization takes on a very significant role. In this work, a comparison between different novel intensity normalization methods is presented. These proposed methodologies are based on Gaussian Mixture Model (GMM) image filtering and mean-squared error (MSE) optimization. The GMM-based image filtering method is achieved according to a probability threshold that removes the clusters whose likelihood are negligible in the non-specific regions. The MSE optimization method consists of a linear transformation that is obtained by minimizing the MSE in the non-specific region between the intensity normalized image and the template. The proposed intensity normalization methods are compared to: i) a standard approach based on the specific-to-non-specific binding ratio that is widely used, and ii) a linear approach based on the α-stable distribution. This comparison is performed on a DaTSCAN image database comprising analysis and classification stages for the development of a computer aided diagnosis (CAD) system for Parkinsonian syndrome (PS) detection. In addition, these proposed methods correct spatially varying artifacts that modulate the intensity of the images. Finally, using the leave-one-out cross-validation technique over these two approaches, the system achieves results up to a 92.91% of accuracy, 94.64% of sensitivity and 92.65 % of specificity, outperforming previous approaches based on a standard and a linear approach, which are used as a reference. The use of advanced intensity normalization techniques, such as the GMM-based image filtering and the MSE optimization improves the diagnosis of PS.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.