Research overview
The text below is the source article’s original abstract under a verified reuse license. cc by
BackgroundThe Mini-BESTest is a clinical balance test that has shown a high sensitivity in detecting balance impairments in elderly with Parkinson's disease (PD). However, its reproducibility between different raters and between test occasions has yet to be investigated in a clinical context. Moreover, no one has investigated the reproducibility of the Mini-BESTest's subcomponents (i.e. anticipatory postural adjustments; postural responses; sensory orientation and dynamic gait). We aimed to investigate the inter-rater and test-retest reproducibility (reliability as well as agreement) of the Mini-BESTest, as well as its subcomponents, in elderly with mild to moderate PD, performed under conditions assimilating clinical practice.MethodThis was an observational measurement study with a test-retest design. Twenty-seven individuals with idiopathic PD (66 - 80 years, mean age: 73; Hoehn & Yahr: 2-3; 1-15 years since diagnosis) were included. Two test administrators, having different experiences with the Mini-BESTest, administered the test individually, in separate rooms in a hospital setting. For the test-retest assessment, all participants returned 7 days after the first test session to perform the Mini-BESTest under similar conditions. Intra-class correlation coefficients (ICC2.1), standard error of measurement (SEMagreement), and smallest real difference (SRD) were analyzed.ResultsThe Mini-BESTest showed good reliability for both inter-rater and test-retest reproducibility (ICC = 0.72 and 0.80). Regarding agreement, the measurement error (SRD) was found to be 4.1 points (accounting for 15% of the maximal total score) for inter-rater reproducibility and 3.4 points (12% of the maximal total score) for test-retest reproducibility. The investigation of the Mini-BESTest's subcomponents showed a similar pattern for both inter-rater and test-retest reproducibility, where postural responses had the largest proportional measurement error, and sensory orientation showed the highest agreement.ConclusionsOur findings indicate that the Mini-BESTest is able to distinguish between individuals with mild to moderate PD; however, when used in clinical balance assessments, the large measurement error needs to be accounted for.
Scientific assessment
Research question
Assess the question within the original study’s scope.
Methods & sample
Check the source article for study design and sample details.
Key findings
An editorially approved findings summary is not yet published for this record.
Limitations
Generalizability, bias and clinical meaning require separate assessment.
Methods, samples and clinical conclusions are not inferred from bibliographic metadata.