Essential Tremor Suppression with a Novel Anti-Tremor Orthosis: A Randomized Crossover Trial.

Mov Disord · 2025-01-21

DOI: 10.1002/mds.30082PMID: 39838596

Open accessResearch Support, Non-U.S. Gov't; research-article; Randomized Controlled Trial; Journal ArticleOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

BackgroundEssential tremor (ET) is characterized by action tremor of the arms, which can interfere substantially with daily activities. Pharmacotherapy may be ineffective or associated with side effects, and stereotactic surgery is invasive. Hence, new accessible treatment options are urgently needed. An easy-to-use and lightweight orthotic device that exerts joint damping may provide an alternative solution for reducing tremor in daily activities.ObjectiveOur goal was to assess the efficacy of a novel anti-tremor orthosis (STIL) in reducing clinical and accelerometry measures of distal arm tremor in ET.MethodsIn a randomized crossover single-blinded trial in 24 ET patients in a hospital setting, we compared three conditions: no orthosis (baseline), a sham device, and the anti-tremor orthosis (order randomized). The orthosis, but not the sham device, passively damped joints in the forearm. Participants performed seven tasks from the Tremor Research Group Essential Tremor Rating Scale (TETRAS). The two co-primary outcome measures were: clinical tremor severity (video-scored TETRAS) and tremor power (accelerometry). Patient satisfaction was self-assessed using the Dutch Quebec User Evaluation of Satisfaction with assistive Technology. Conditions were compared using Wilcoxon signed-rank tests.ResultsThe anti-tremor orthosis significantly reduced TETRAS scores compared to sham and baseline (baseline: 19.0 ± 3.2, sham: 13.7 ± 3.9, orthosis: 9.9 ± 3.6; mean ± standard deviation). Similar effects were observed for tremor power, which was reduced by 87.4% (orthosis vs. baseline) and 59.5% (orthosis vs. sham) across all tasks. A total of 71% of participants were (very) satisfied and 12.5% reported minor adverse events (discomfort/redness of skin).ConclusionThe anti-tremor orthosis had a clinically relevant tremor-reducing effect in ET in a controlled setting, offering potential for a new treatment to manage ET in daily activities. © 2025 The Author(s). Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.