SCIENTIFIC HUB

Follow the evidence.

SCIENTIFIC LITERATURE · MED

Validation of deep-learning-based MRI-to-CT attenuation correction for striatal and extrastriatal [<sup>123</sup>I]I-FP-CIT SPECT measurement.

Neuroimage Clin · 2026-06-06

DOI: 10.1016/j.nicl.2026.104020PMID: 42263402

Open accessresearch-article; Validation Study; Journal ArticleOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

PurposeAttenuation correction is critical for accurate SPECT brain imaging and to quantify uptake ratios in neurological and psychiatric disorders. This prospective study aimed to validate the use of deep-learning-based magnetic resonance to synthetic computed tomography (DL-MRAC) attenuation correction by quantifying striatal and extrastriatal binding of [123I]I-FP-CIT to dopamine and serotonin transporters in Parkinson's disease patients.MethodsSynthetic CTs were generated from T1-weighted MRIs acquired in 12 Parkinson's disease patients using a validated 3D residual U-Net for attenuation correction of [123I]I-FP-CIT SPECT scans. We tested for equivalence of DL-MRAC versus CT-based attenuation correction (CTAC). We further compared uniform correction using Chang's method (UAC) and no attenuation correction (NAC) for regional analysis of specific binding ratios (SBRs) in striatal and extrastriatal areas. Data from the Parkinson's Progression Markers Initiative were used for external validation (n = 18).ResultsAs compared to CTAC, mean bias of DL-MRAC SBRs was -0.4% (95% confidence interval, CI -1.2 to 0.4) in the striatum and - 0.1% (95% CI, -0.8 to 0.6) in extrastriatal areas. UAC overestimated SBRs with mean bias ranging from 7.5% to 12.4%, whereas NAC underestimated SBRs with mean bias ranging from -6.5% to -24.0%, for striatal and extrastriatal binding estimates in all cohorts.ConclusionDL-MRAC is a valid, radiation-free method for attenuation correction and quantification of [123I]I-FP-CIT binding to dopamine and serotonin transporters in subjects undergoing DaTSPECT examinations. It outperforms UAC and NAC and may therefore serve as a valuable alternative for patients for whom MRI is available and for data acquired on SPECT-only cameras.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.