SCIENTIFIC HUB

Follow the evidence.

SCIENTIFIC LITERATURE · MED

Brain Clearance of Contrast Agent in Intravenous DCE-MRI Is Measurable and Cannot Be Explained by Clearance Across the BBB Alone.

Magn Reson Med · 2026-07-18

DOI: 10.1002/mrm.70514PMID: 42470230

Open accessresearch-article; Journal ArticleOriginal source ↗

Research overview

The text below is the source article’s original abstract under a verified reuse license. cc by

PurposeTo determine the feasibility of measuring brain clearance of gadolinium contrast agent using standard intravenous DCE-MRI acquisitions and evaluate the contribution of blood-brain barrier (BBB) and non-BBB clearance routes.MethodsUptake and extended Tofts models were fit to DCE-MRI data from people with Parkinson's disease, post-stroke and controls. Models were compared using the Akaike information criterion. Key parameters (Ktrans, vp, ve, and k) were extracted from gray and white matter ROIs. In mice, two-photon microscopy of intravenously injected Sulforhodamine 101 was used to confirm small tracer clearance kinetics without the confounds of partial volume effects or water exchange.ResultsThe extended Tofts model provided a superior fit compared to all uptake-only models. Extended Tofts estimates of the extravascular extracellular volume fraction ve were underestimated by a factor of 10-20 compared to known literature values (1.5% vs. 20%-30%). We hypothesized this bias may be due to an additional competing non-BBB clearance mechanism not accounted for by the extended Tofts model. In both MRI and two-photon data, we found that ve estimates trended toward literature values as BBB permeability (and thus BBB clearance) increased, supporting our hypothesis.ConclusionModeling clearance of extravasated contrast agent from the brain improves fit quality compared to models that neglect clearance. Estimates of interstitial volume fraction were underestimated at low Ktrans but tended toward literature values as BBB permeability (and clearance) increased. This study indicates that estimating brain clearance of contrast agent using DCE-MRI is feasible, and that estimates reflect a combination of BBB and non-BBB clearance pathways.

Scientific assessment

01

Research question

Assess the question within the original study’s scope.

02

Methods & sample

Check the source article for study design and sample details.

03

Key findings

An editorially approved findings summary is not yet published for this record.

04

Limitations

Generalizability, bias and clinical meaning require separate assessment.

Methods, samples and clinical conclusions are not inferred from bibliographic metadata.